ruskin dampers. 8955From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. ruskin dampers

 
8955From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damperruskin dampers 025" thick formed aluminum with concealed blade linkage, synthetic bearings and non

Ruskin CFD model ceiling fire dampers provide the appropriate protection needed for openings in fire rated ceilings. 2. It features: AMCA Class 1A leakage for energy savings R value – 2. Our plant in Thailand is well-equipped to manufacture next-generation products. Ruskin July 2020 Page1 CD60DC (DATA CENTER) High-performance Galvanized Steel Airfoil Blade Damper AMCA Class IA Leakage Rated The CD60DC is designed for HVAC systems serving data center facilities where high performance and reliability is expected. 8955DIBD20, 40, 60 fire dampers can be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. 21. Ruskin’s Information is not a. We service the Mechanical Contractor and Mechanical Engineering community in Southern California. Fire/smoke dampers ordered with pneumatic actuators may be ordered with the EFL and and. 165°F or 212°F (74°C or 100°C) (specify temperature) fusible volume adjustment options are available. It features: Accurate airflow and isolation at extreme elevated temperatures. We are the leading manufacturer of air and sound. • For proper operation, damper must be installed square and free from. Ruskin pressure drop testing was conducted in accordance with AMCA Standard 500-D using Figure 5. Concealed linkage out of the airstream for low maintenance and reduced air turbulence. cealed in the frame. static pressure. Actuators and accessories are factory mounted on the right side when viewed from the actuator side of the wall or floor. (Consult for electronic version of this “Quick” spec as well as for complete 3- part CSI MasterFormat Specifications) Document Title Limited Warranty Document LINKS TO IMPORTANT DOCUMENTSFire and Smoke Dampers Ruskin actionair ES Series Operating And Maintenance Manual. All installations shall be in accordance with manufacturer's published installation instructions. Ruskin's Commercial Control Dampers provide superior air control, high performance, and sustainable energy efficiency. Masonry/Wall or Floor: #10 s elf-tapping concrete screws. lbs. appliCaTion CFD7 is the first Ceiling Radiation Damper to be UL listed for 2” x10” or 2” x 12” wood joist assemblies (Ref. Auto-Balancing. The switch package shall include two position indication switches linked directly to the damper blade to provide full open and full closed damper. , Ruskin does not recommend using these designs in systems with velocities greater than 2000 fpm. 4 inches w. CFD7T - 2"x4" Truss Assemblies (Ref. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. Designed to protect life and property, Ruskin® manufactures a complete line of UL classified dampers. Greaves Rd. INSTALLATION For proper operation, damper must be installed square and free from racking. Damper widths from 12" to 60" (305 to 1524) wide shall not leak any greater than 8 cfm sq. COMMERCIAL CONTROL, MANUAL, AND. Built from strong materials and designed on state-of-the-art equipment, they are perfect for demanding conditions. A. Static only damper labels are not permissible. UL approval for dual directional air flow. g. The CDR82 Round Control Damper features: Accurate airflow control within round ductwork systems in medium pressure industrial HVAC systems Desired performance easily attained in pressure differentials of 6"w. The FSD60FA da mper may be installed. Determine area factor for damper by entering the Area Factor Table through duct width and height. (Consult for electronic version of this “Quick” spec as well as for complete 3-part CSI MasterFormat Specifications)Ruskin model ABD offers HVAC design engineers an automatic balancing damper which provides: • Energy savings to building owner • Constant maintained airflow volume • Good indoor air quality • Anti-microbial agent prohibiting bacteria or mold growth • Easy installation; requires no tool for adjustment. It is recommended for heavy duty applications using multi-section dampers where either unison or sequence operation is required. Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. The DIBD20, 40, 60 carry a 1 1/2 hour UL fire damper label and are classified as a dynamic damper for use in HVAC systems that remain in operation during a fire. , with order). Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) lo ng welds. Hexagonal axles that ensure a positive lock with blades. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Ruskin - Dampers Louvers (816) 761-7476 Subject The FSD35 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that provides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. The EFL is standard on all fire/ smoke dampers ordered with electric actuators. For best pressure drop and sound perfor-mance at higher velocities, consider an airfoil blade damper, such as Ruskin model CD60. g. 2. 6 psi to 44. Greaves Rd • Kansas City, MO 64030 P: (816) 761-7476 (816) 765-8955 F: E: ruskin@ruskin. Dampers shall be Ruskin CD60 model. Website: AUTHORITY IN AIR CONTROL Phone: (816) 761-7476. for dampers up to 6 sq. This catalog offers Damper customers an easy to use buying guide for miscellaneous Ruskin Damper parts. Issue ‘E’ Fuse Link 4. The CD60GS is designed to provide maximum combustion air and pressure relief quickly for emergency generator start up to avoid damage of equipment orsurrounding space. Commercial Dampers; Diffusers; Economizers; Energy Recovery Ventilators; Industrial Dampers; Life Safety Dampers; Louvers & Architectural; Pressure Relief Doors; Noise. Noise Control. used in conjunction with Ruskin fire/smoke dampers. The CD82HT Industrial Control Damper has an 8" frame. Damper shall be in all respects equivalent to Ruskin BD6. g. Ruskin fire dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. It features: 1-1/2 hour rating. Consult Ruskin or your Ruskin repre-sentative when damper is to be applied in conditions exceeding recommended maximums. Readily connects to round spiral or flexible ductwork. Brand: Ruskin SKU: CDR92. FILES (0) Share this page: Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. The DIBD2/OW can be installed on either side of the wall or top or bottom side of the floor. They also offer a new coupler option that joins two damper sections without a jackshaft allowing an actuator to be mounted on side of frame to provide a narrow profile when space is limited. After 15 minutes, the damper is closed and reopened. w. Rectangular Silencers. 125" (3. ft. upstream of the damper. Figure 5. The CD60SS in 304 stainless steel construction offers corrosion resistance and Class IA leakage performance of 3cfm/ft @ 1" w. Unless specifically ordered otherwise, when looking at the concealed linkage side of the damper and the bottom blade turnsA. Sizes to fit round openings up to 20" diameter and rectangular openings up to 24" x 24" are available. Dampers shall be in all respects equivalent to Ruskin Model CD40. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowShare this page: Combination Fire/Smoke dampers are low leak damper and actuator assemblies that have passed the UL555 and UL555S test requirements. 3 (damper installed with duct upstream and downstream). (Consult Ruskin for detailed CSI MasterFormat Specification. MINIMUM SIZE Vertical Installation – 4"w x 4"h (102 x 102). All calculations are with external mounted actuators and accessories. The barometric bypass dampers relieve excess air in duct systems through the use of a counter-balanced controlled arm weight. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. Nailor manufactures a unique and comprehensive line of products essential for a well designed HVAC system. Learn more about the features, specifications and dimensions of the PVC12 damper from Ruskin, the leading manufacturer of air control. g. Unequal section sizes. emergency, dampers and their actuators alike may be required to operate at elevated temperatures. Ruskin fire/smoke dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. DIMENSIONAL DETAILS SUGGESTED SPECIFICATION 3900 Dr Greaves Rd. Kansas City, MO 64030Leakage ratings are based on AmCA Standard 500 using Test Setup Apparatus Figure 5. Fusible Link which is included at no extra charge. (2) 1/4-20 Nuts 2. Greaves Rd. Dampers shall be Ruskin model FSDR25. The most effective method of energy-saving insulation. g. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Ruskin Literature. g. The. 11-17-20. com W: Ruskin® manufactures an extensive line of UL-rated and listed dampers to protect your life and property. Ruskin recommends appropriate bracing to support the damper horizontally at least once for every 8 'of. Counterbalance weights that can be set to relieve air pressure differentials less than . (0. Website: AUTHORITY IN AIR CONTROL Phone: (816) 761-7476. 5. G Bolt Circle Diam. See “Combination Fire Smoke Damper Multiple Section Detail” specRuskin February 222 Page 1 FDR25SS Stainless Steel True Round Fire Damper 1 1/2 Hour UL555 Ratings for use in Dynamic & Static Systems Ruskin FDR25SS is a stainless steel true round fire damper designed for use in fire rated walls and floors in either Static or Dynamic systems. Zone Control Systems. Dimensions shown in parentheses ( ) indicate millimeters. Actuators & Damper Accessories Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. 25" w. UL qualifies the damper and its actuator for performance after 30 minute exposure to elevated temperatures. Conservative ratings are pre-sented intentionally in an effort to avoid misapplication. Ruskin was founded in the Ruskin Heights area of Kansas City in 1958. Select from manual cable drive control to fully automated pressure depended and pressure independent. Ruskin manufactures an extensive line of UL rated and listed dampers to protect life and mitigate property loss during a life safety event. The majority of designs are rated at 2 or 3 hours. Greaves Rd • Kansas City, MO 64030 P: (816) 761-7476 (816) 765-8955 F: E: ruskin@ruskin. Home; PRODUCTS Air Control and Backdraft Dampers Ceiling Radiation Dampers. Ruskin May 2020 Page 1 Models CFD(R)2, CFD(R)3, CFD(R)3. Corrosion. This damper is fitted with a counterweight assembly that can be field adjusted and calibrated to meet the specific airflow requirements of your unique system. From light duty commercial applications to heavy duty industrial and process applications, Ruskin's comprehensive product portfolio includes high performance quality for every application. static pressure. It is a one hour fire rated, UL labeled Corridor Damper and a 11/2 hour fire rated, Leakage Class 1, UL labeled Combination Fire Smoke Damper. to. and a maximum of 3 CFM sq. Each has added features that enable them to meet all high temperature, high pressure airflow modulation and shutoff. FSD35. Dampers can be constructed of galvanized, stainless, or aluminum and are available with a diverse compliment of. The CFD7T-SR is a UL Classified Ceiling Fire Damper listed for installation in wood truss floor/ceiling and roof/ceiling designs L528, L546, L558, L574, L585, L586, L592, P533, P545, P548, P572, and H502. 2. 761. Learn about the features, specifications and benefits of different series of Ruskin products, such as TDP05K, CD60, CD50, CD40,. 25" w. Mounting Angle Fastener Spacingon dampers with v-groove blades, we recommend sizing dampers for 1,500 fpm. Product• Ruskin FAST Angles • One piece angle shipped with the damper • Available in 1-½" or 2-½" • Metal, wood and masonry walls/floors • Permits damper installation before or after drywall installation • Approved for all Ruskin fire, smoke and fire/smoke dampers LaBOr Saver #2 IntegraL and factOry SLeeveSRuskin® has the largest selections of AMCA certified dampers in the industry. Standard, 1 1/2 and 3 hr. Ruskin® Labor Saversfor fire and fire/smoke dampers include factory sleeves, PFMA mounting angles, and tagging by floor or by area. static pressure. Ruskin smoke damper and actuator assemblies qualify. Maximum 8" static pressure. 2. ft. SUGGESTED SPECIFICATION • When used in fan discharge applications, damper should be located at least one-half the fan diameter away from the fan. 7476 Fax: 816. 3 m/s) and 8” w. Ruskin is a leading manufacturer of dampers, louvers, air measuring, noise control and energy recovery products for various applications. Higher velocities are not recommended for outside air openings, due to water penetration concerns. The Model IBDT is a thinline fire damper that can be installed vertically in walls and partitions or horizontally in masonry floors with fire resistance ratings of less than 3 hours. INSTALLATION CD355 SERIES DAMPER IS NOT RECOMMENDED FOR INSTAL- Ruskin August 2020 Page4 CONSTRUCTION & DIMENSIONAL INFORMATION Multi-section Dampers Dampers over the maximum single section size will require multiple damper sections, typically built in equal sizes. Ruskin® offers a comprehensive guide to its commercial dampers, including product features, specifications, installation instructions, and 3D Revit® files. Maximum rating of 4,000 fpm and 8" w. Fire/smoke dampers ordered with pneumatic actuators may be ordered with the EFL and an EP (electro/pneumatic) switch. To meet the diversity of fire and smoke protection requirements,. FILES (0) Share this page: Constructed of premium vinyl ester resins, Ruskin’s fiberglass airflow control products are ideal for installations in corrosive environments such as waste water treatment, micro-electronics fabrication, pulp and paper mills, air pollution control systems and corrosion resistant air exhaust and. Fiberglass Dampers. consider an airfoil blade damper, such as Ruskin model CD60. It features: Static Ceiling Fire (Radiation) Damper Use in Fire Resistive Floor/Ceiling or Roof/Ceiling Assemblies 165 ֯ F or 212 ֯ F Fusible Link Blade Insulation CSFM 3225-0245:0101. CDR25 and CDO25 dampers are round and oval volume control dampers. Each fire damper shall be labeled for use in dynamic systems. Call (847) 773-0645. W. Dynamic fire dampers shall be Ruskin multiple model DFD60. Phone. 4 inches w. Masonry/Wall or Floor: #10 self-tapping concrete screws. 761. “Out Of Wall” Grille Access Fire Dampers 1 1/2 Hour UL555 Rated | For Dynamic & Static Systems DIBD2GA are dynamic fire dampers designed for “out of wall” applications. a. Access Doors. Industrial FAQs. Greaves Rd. Hours: 9am - 5pm CDT M-F. 3. Ruskin fire/smoke dampers. Ruskin model CD50 offers HVAC design engineers an ultra-low leak high performance damper which provides; • Energy savings for building owners • Low noise generation and lowest pressure drop • Low maintenance. UL 555/555S 1. The Ruskin Wireless Inspector™ includes the RFDI (Radio Frequency Damper Interface) located at each damper withCeiling Fire Dampers UL Classified Radiation Dampers for Wood Truss Construction The CFD7T is a UL Classified Ceiling Fire Damper that is UL listed for installation in wood truss floor/ceiling and roof/ceiling designs L528, L546, L558, L574, L585, L586,. RectangulaR DampeRs CD40, CD50, CD60 SerieS DeSCripTiOn The ruskin CD40, CD50, CD60 parallel and opposed-blade HVAC control dampers are custom made-to-order. The AiQ-TD-50 offers accurate airflow measurement and control through electronicthermal dispersion technology utilized in Ruskin model TDP05K Airflow & Temperature Measuring probes(s) with the inclusion of Ruskin model CD50 control damper factory configured as one compact assembly. 7447 Toll Free: 800. Actuators and Damper Accessories. Spec CBD4-507/Replaces CBD4-92000 ©Ruskin 2007 *Unit furnished approx 1/4" (6). It features: Maximum velocity of 4,000 fpm. It features: Fire and heat protection where HVAC components penetrate the ceiling membrane. 8) galvanized steel struc-Products. Spec AIRFLOW-IQ-0121 STATD SPTS R ST T TT T R T. The industrial grade backdraft dampers offer rugged construction and heavy gage materials to withstand the high velocities and back. Standard features vary by model to make application selection straightforward. We offer a wide variety of products to mee. Higher velocities are not recommended for outside air openings, due to water penetration concerns. Get a Quote. Ruskin Literature. Get free shipping on orders over $999!%PDF-1. ft. The Damper part prices in this catalog do include freight within the contiguous 48 states. The PVC12 damper is a corrosion-resistant and low-maintenance device that can regulate air flow in ducts or pipes. Our line of outside air dampers are available in 0% - 35% range or 0% - 100% range, and all are easy to install with factory-provided plugs. Static pressure and CFM are corrected to. This highly functional “true round” backdraft damper eliminates the need for transitions when flange-mounted to round duct installations and is fitted with a counterbalance assembly that canRuskin May 2020 Page 1 CFD4 Ceiling Fire Damper UL Classified Radiation Dampers. Out of wall “OW” fire dampers are designed so that the leading edge of the damper frame can be up to 8" (203) out of the wall, partition or masonry floor. The SD60M is a UL555S Classified Leakage Class I modulating smoke damper. g. Dampers shall be Ruskin Swartwout Series Model CBDR912. • Kansas City, MO 64030 • (816) 761-7476 • FAX (816) 765-8955 INDUCT MOUNT CONTROL DAMPERS It features: Maximum velocity of 4,000 fpm. The CFD7 is UL555C Classified Ceiling Fire Damper for wood construction. Higher temperature ratings available consult Ruskin. Non-stick, noncorrosive bearings that assure. Life Safety Dampers. g. • Airfoil High Performance Dampers • Triple-V Standard Performance Dampers • Ruskin Exclusive True Round Dampers • Ruskin Fast Mounting Angles • Complete Corridor. Steel construction with aluminum paint finish. The FSDR60 is the ideal choice when round duct is used on a project. A 1" (25) diameter jackshaft is normally used. Multiple section damper assemblies may require brac - ing to support the weight of the assembly and to hold against sys - tem pressure. Multiple section damper assemblies may require brac - ing to support the weight of the assembly and to hold against sys - tem pressure. FILES (0) Share this page: Trusted for decades, Ruskin V-Groove blade dampers were designed to extend a lower cost solution for standard duty (medium or low pressure) applications. Ruskin blast suppression dampers have been designed for peak reflective pressures from 1. Determine the airflow in CFM. Rusin anuary 2021 Replaces Spec AIRFLOW-IQ-01 Pae 4 High Performance Ruskin Control Damper Model CD50 • Low Leak, extruded aluminum damper for higher velocity and pressure HVAC systems. For damper styles WR, WC, WO and BC only the duct connection portion extends through the wall and the damper. Actuators are designed to operate reliably in smoke control systems requiring Underwriter’s Laboratories, Inc. (2 kPa). Swartwout series model 914 Heavy Duty Fiberglass Round Control Damper • Accurate control of airflow through the round duct • Designed specifically for corrosive environments • Premium constructed Vinyl Ester, Flange Mounted, single piece blade has 3 frame styles • Designed to withstand pressures up to 30" wg Differential PressureRuskin's premier damper for medium pressure commercial and industrial HVAC systems offers the lowest leakage available with a standard, commercial built damper. (1 kPa) static pressure and shall be tested and rated to close with airflow in either direction. The FSD60 can be installed in horizontal or vertical applications and has low leakage and pressure drop ratings. Shop custom order Ruskin Dampers and Airflow products for your HVAC needs. For up-to-date information visit CFD . Noise Control. 500. Space fasteners 6" (152) on center and a maximum 2" (51) from the ends of the joining sec-tions or from each corner. ©Ruskin February2016 Model FSD60GA and FSD36GA series meet the requirements for combination fire and. Combination louvers can incorporate both drainable and non-drainable blades which are selected based on the structure. Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. Website: AUTHORITY IN AIR CONTROL Phone: (816) 761-7476. Ruskin Brands and Locations. Expansion Clearance – The opening in the wall or floor must be a minimum of 1/8" per foot (3 per 305) larger than the overall damper/sleeve assembly. If the actuator must be mounted on top or bottom, select the FSD60V. back pressure depending on damper size. Conservative ratings are pre - sented intentionally in an effort to avoid misapplication. What is an EFL device? The Ruskin electronic "resettable" fuse line (EFL) is a UL Classified heat response device for use in conjunction with Ruskin fire/smoke dampers. AUTHORITY IN AIR CONTROL The (D)IBD20G meets the requirements for fire dampers established by: National Fire Protection Association NFPA Standards 90A and 101 ICC International Building Codes CSFM California State Fire Marshal Fire Damper Listing (#3225. The integral frame and unique “cinch plate” design provides a low cost, high performing damper. Noise Control. Specifier Select Options. Ceiling dampers are to be factory installed in a 111/2" (292) tall R6 insulated ductboard box with a 1" (25) turned out flange and 1/2" (13)an AMCA registered laboratory. Relief doors open automatically to prevent ductwork from imploding or exploding due to differential pressure. Offset single blade design lets Ruskin engineers calibrate the damper operation to exact customer specification. Commercial dampers provide low-pressure openings with excellent pressure-drop performance. Ruskin Company certifies that the SD50 shown hereon is licensed to bear the AMCA Seal. 350° Vertical or Horizontal SIze StAtIC PReSSURe teMPeRAtURe INStALLAtIoN ACtUAtoR ReqUIReMeNtS * UL555S requires that all. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowon dampers with v-groove blades, we recommend sizing dampers for 1,500 fpm. The CBD2 is an extremely sensitive gravity operated backdraft damper. Material thickness shall be equivalent to Ruskin model CDR25 or CDO25 standard construction. Masonry/Wall or Floor: #10 self-tapping concrete screws. CD60 | Galv. Refer to the UL approved installation instructions for specific requirements. While providing fresh air intake and exhaust, Ruskin Louvers can also provide architectural style to building design. It also features: Frame corners that are internally braced to reduce racking. The airfoil blades are designed for HVAC systems with velocity and pressures up to 4,000 fpm and 8" w. 765. 3 sq. Multiple models are intended for diverse heavy duty applications, and can be manually or automatically controlled using factory installed and commissioned actuators. Learn more about the features and. Unlike conventional mounting angles that can-not be fastened together in the corners and ship separately from the dampers, the FAST and PFMA are: • One piece angles (fastened together in the corners)- Single section dampers ordered with either 12” (305), 14” (356) or 16” (406) long sleeve; the IBD20, 40, 60, 230, 430 and 630 models may be substituted. Horizontal mount dampers may be installed with the jackshaft above or below the floor. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. 2) wall thickness with 12 gage (2. Ruskin fire dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. 3 (damper installed with duct upstream and downstream). Damper shall be equivalent to Ruskin model ARD25. angles together at corners of dampers. /Class III, V-Groove Blade,. Dampers shall be in all respects equivalent to Ruskin model CBD6. The FSDR60 is a "true round" Class 1 leakage rated combination fire and smoke damper designed for use in metal, wood or concrete fire and smoke rated partitions and concrete floors. a. The uick Product Selection Reference Guide assists in selecting the appropriate Ruskin® Product for your application. When ordered, as an option, the DTS will beThe DFD60 is a UL555 classified, 1 1/2 hour rated, multiblade fire damper. Ruskin Model ZCDR25 can be installed into existing round ductwork. Keywords: Ruskin, Commercial, backdraft, damper S3G, Data, Submittal, galvanized, steel Created Date: 1/5/2017 12:58:19 PMRUSKIN finishes enhance product appearance to blend with other colors selected. Welcome to Ruskin Rooftop Systems 972. 350° Vertical FSD36 144"x 96" 4"w. Ruskin September 2021 Page4 CONSTRUCTION & DIMENSIONAL INFORMATION Ruskin CD50GS is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the. Ruskin Green Products. Constructed of premium vinyl ester resins, Ruskin’s fiberglass airflow control products are ideal for installations in corrosive environments such as waste water treatment, micro-electronics fabrication, pulp and paper mills, air pollution control systems and corrosion resistant air exhaust and collection systems. The Quick Product Selection Reference Guide assists in selecting the appropriate Ruskin® Product for your application. Each has added features that enable them to meet all high temperature, high pressure airflow. added to the damper at fabrication. Stops the leakage of smoke in static and dynamic smoke systems. Every damper is built with performance in mind and tested per AMCA standards. static pressure. • Operation Test The damper/actuator assembly is exposed to heated (250ºF or 350ºF) airflow (minimum 2,400 fpm and 4. L586) Ceiling fire dampers maintain the integrity of fire resistive ceiling assemblies constructed from wood True Round Grille or through ceiling membrane penetrationRuskin February 222 Page 1 FDR25 Galvanized Steel True Round Fire Damper 1 1/2 Hour UL555 Rating for use in Dynamic & Static Systems Ruskin FDR25 is a true round fire damper designed for use in fire rated walls and floors in either Static or Dynamic systems. A change anywhere is a change everywhere, instantly!2. 5 Hour for use in 2 Hour Walls. Static pressure and CFM are corrected to . Noise Control. All (D)IBD Curtain Type Fire Dampers Excluding IBDT Series model – FLIB fd fuse link assembly 1. While providing fresh air intake and exhaust, Ruskin Louvers can also provide architectural style to building design. Greaves Road Grandview MO 64030 Phone: 816-761-7476 ruskin@ruskin. Axles shall be square or hexagonal positively locked into the damper blade. The industrial grade backdraft dampers offer rugged construction and heavy gage materials to withstand the high velocities and back. When used in fan discharge applications, damper should bethe damper frame. Damper shall be tested and licensed in accordance with AMCA 511 for Air Performance and Air Leakage. We always proudly labeled our literature with the AMCA Certified Ratings Logo and now we will be labeling on dampers as well. g. Noise Control. Catalog. 0) sleeve. Ruskin ® Terms and Conditions for more information. Life Safety Products; Louver and Architectural; Louver Paint Finishes - Color Guide; Diffusers; Energy Recovery Ventilators; Commercial Control DampersRuskin - Dampers Louvers (816) 761-7476 Subject: The FSD60FA is a combination fire/smoke damper that allows through the grille access to the damper, actuator and heat actuated device. 761. Dampers For More Information: Manufacturer's Site. Share this page: From light operations to heavy-duty industrial applications and from backdraft control to indoor air quality control, Ruskin provides the perfect control. Axles that positively lock to blades without screws or welds. ) SUGGESTED SPECIFICATION STATIC PRESSURE (Inches Water Gage) AIR FLOW IN C. Innovative thermally efficient dampers are fabricated utilizing high yield 6063T6 frame and blade extrusions. Unless specifically ordered otherwise, when looking at the concealed linkage side of the damper and the bottom blade Ruskin FDR25 is a true round fire damper designed for use in fire rated walls and floors and is the perfect choice when using round duct. Every damper is built with performance in mind and tested per AMCA standards in Ruskin's Laboratory. Innovative thermally efficient dampers are fabricated utilizing high yield 6063T6 frame and blade extrusions. With the variety of models, sizes, and paint finishes available, Ruskin Louvers can add unusual and appealing features to exterior and interior elevation. Greaves Rd. These dampers are commonly used for vapor cloud and dust cloud explosions found in petroleum, chemical, defense, government, dust collector,. All Ruskin fire smoke dampers meet or exceed the minimum UL555S requirements. Air control dampers (6 pages) Fire and Smoke Dampers Ruskin TS150 Operation Instructions (2 pages) Summary of Contents for Ruskin DIBD2. 3. Excellent weather protection when installed in. g. Fiberglass Series round backdraft dampers. 5" w. The critical environment damper series is designed and manufactured with all the necessary features required to withstand the elements of coastal and corrosive applications. Our History. Masonry Wall or Floor: #10 s elf-tapping concrete screws Wood/Steel Stud Wall: #10 screws. Ruskin fire dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. A 1" (25) diameter jackshaft is normally used for. Multiple section dampers are available in unlimited sizes. 5. ft. The CFD2 is a UL555C Classified Ceiling Fire Damper. com W: Genset dampers are designed to provide maximum combustion air and pressure relief quickly for emergency generator start up to avoid damage of equipment or surrounding space. Ruskin fire/smoke dampers can be rotated or turned over to accommodate the application.